  1. flexible drain line & P trap ?'s - InterNACHI®️ Forum

    2012年4月26日 · Just look at, and remember, all the plumbing drain pipe components involved. 3 basic plumbing parts for you to glean. Trap adapter, Trap and Trap Arm. In this case provided by the OP, P-Trap & Trap Arm. A: The Trap Circumference. B: Trap Arm interior not smooth. 3: …

  2. flexible drain line & P trap ?'s - InterNACHI®️ Forum

    2021年3月26日 · do y’all know if the flexible drain line is permissible in Austin, TX? It is not…if you are a licensed plumber.

  3. Flex Trap - Plumbing Inspections - InterNACHI®️ Forum

    2012年7月18日 · “Insert Location” sink had a temporary flexible corrugated drain pipe installed. This type of drain pipe is prone to frequent clogging. Recommend qualified plumber replace with a standard ridged smooth wall drain pipe and P-trap.

  4. Flexible bathroom sink drains - InterNACHI®️ Forum

    2014年7月2日 · Are the flexible sink tails/p-traps acceptable? ... Flex Trap. Plumbing Inspections. 11: 4868: July 19, 2012

  5. trap diagram - Plumbing Inspections - InterNACHI®️ Forum

    2014年4月28日 · Trap under floor is not really a p-trap, with vent opening below the trap weir, though the trap should prevent sewer gases. Not sure if removing S-trap would make any difference. belliott (Bob Elliott, 450.0002662) April 30, 2014, 1:03am

  6. Dual P-traps for Kitchen Sink? - InterNACHI®️ Forum

    2020年11月15日 · A removable P-trap with slip or ground joint connections can serve as a cleanout for drain piping that is one size larger than the P-trap size. Source 2015 or 2018 IPC. mwilles (Martin Willes, CMI) November 15, 2020, 8:48am

  7. If you see this flexible pipe under sink, do you point it out in 4 ...

    2023年5月17日 · One of my inspector friend give me the suggestion is to write: “flexible draining pipe only considered as temporary repairs and tends to clog. Solid PVC pipe is recommended” ddagostino (Dominic DAgostino, CMI HI3957) May 17, 2023, 12:31pm

  8. Two P traps under sink - two fixtures - InterNACHI®️ Forum

    2020年6月17日 · I would point out that generally the sink drain and garbage disposal “tee” together before the P trap. I would call it a questionable installation. I’m not certain the plumbing code would have accepted a wye right there but since we aren’t code inspectors I would leave it as questionable with further evaluation by a qualified plumber.

  9. P-Trap Required With Grease Trap? - InterNACHI®️ Forum

    2005年7月1日 · I am not a plumber, but a Commercial Builder, and think that a pea trap is not required with the use of this grease trap, for I believe it is creating the trap required. I might be wrong, but sure someone will respond and comment to my comment. Hope this helps. P. S. I believe someone will quote a code on this issue and put you at ease. Marcel

  10. S-Trap or Poorly Done P-Trap? - InterNACHI®️ Forum

    2021年3月19日 · Two things are needed to create an s-trap out of a p-trap that connects to a vertical drain pipe: a) short trap arm (less than 2x its pipe diameter) b) lack of vent. If you only have [A], then it’s a crown vent, also not allowed in most areas. If you only have [B], then it’s a p-trap without a vent, not an s-trap.